Muscle press
  • AttributeValue
    Electrical connection24-pin IEEE 488 female (SysLink)
    Analog Terminal
    Pneumatic connectionTube with 4 mm outer diameter
    Operating voltage24 VDC
    Operating pressure6 bar
    I/O2 DI / 3 DO / 2 AI / 1 AO
    Press force actuation2x Pneumatic muscle
    Maximum allowed force for each muscle: 630 N
    Maximum allowed force for station: 100 N per muscle
    Press force measurementLoad cell
    0 - 200 N
    Pressure regulationProportional pressure regulator
    Pressure range: 0,06 - 6 bar
    Dimenions (H x W x D)525 mm x 240 mm x 185 mm

  • Application module interface (Syslink or analog terminal)
    DescriptionReferenceDatatypeAddress
    CP Lab
    Address
    CP Factory
    Inputs
    TRUE = Back cover present+HL-BG1Bool%I0.0%I2.0
    Current force (0 V = 0 N, 10 V = 200 N)+HL-KF10:12Word%IW43%IW6
    Current pressure (0 V = 0 bar, 10 V = 6 bar)+HL-KF11:XWord%IW46%IW8
    TRUE = Pressure setpoint reached+HL-KF11:D3Bool%I0.4%I2.4
    Outputs
    TRUE = Open emergency stop valve+HL-MB1Bool%Q0.0%Q2.0
    Set pressure setpoint (0 V = 0 bar, 10 V = 6 bar)+HL-KF11:W+Word%QW43%QW6
    Regulator behavior bit 0 (0 = selection via display, 1 = fast, 2 = standard, 3 = precise)+HL-KF11:D1Bool%Q0.4%Q2.4
    Regulator behavior bit 1 (0 = selection via display, 1 = fast, 2 = standard, 3 = precise)+HL-KF11:D2Bool%Q0.5%Q2.5

    • QR marker
    • QR marker
    • Circuit diagrams (up to Q1/2017)
    • Circuit diagrams (up to Q1/2017)