Measuring v2
  • AttributeValue
    Operating voltage24 V DC
    Sensors2x Sick OD Mini OD1-B100H50U14
    Dimensions (L x B x H)273 mm x 240 mm x 558 mm
    Weight4 kg
    InterfacesSyslink, analog terminal

  • Application module interface (Syslink or analog terminal)
    DescriptionReferenceDatatypeAddress
    CP Lab
    Address
    CP Factory
    Inputs
    TRUE = Work piece present+BG-BG1Bool%I0.0%I2.0
    Distance measurement BG2 (0V=0mm - 10V=40mm)+BG-BG2:QAWord%IW43%IW6
    Distance measurement BG3 (0V=0mm - 10V=40mm)+BG-BG3:QAWord%IW46%IW8
    Outputs
    Signal light - red on+BG-P1-PF1Bool%Q0.0%Q2.0
    Signal light - green on+BG-P1-PF2Bool%Q0.1%Q2.1
    Signal light - blue on+BG-P1-PF3Bool%Q0.2%Q2.2
    Signal light - 1=Flash, 0=Permanent on+BG-P1-FLBool%Q0.3%Q2.3
    Sensor BG2 - Teach (see sensor manual, table "Timing")+BG-BG2:MFBool%Q0.4%Q2.4
    Sensor BG3 - Teach (see sensor manual, table "Timing")+BG-BG3:MFBool%Q0.5%Q2.5

    • QR marker
    • QR marker
    • Front cover label
    • Front cover label