Measuring
  • AttributeValue
    Electrical connection24-pin IEEE 488 female (SysLink)
    Analog terminal
    Operating voltage24 VDC
    I/O5 DI / 3 DO / 2 AI
    Sensors2x optoelectronic distance sensor
    Dimenions (H x W x D)396 mm x 255 mm x 777 mm

  • Application module interface (Syslink or analog terminal)
    DescriptionReferenceDatatypeAddress
    CP Lab
    Address
    CP Factory
    Inputs
    TRUE = Work piece present+BG-BG1Bool%I0.0%I2.0
    Distance measurement left (4 mA = 0 mm, 20 mA = 40 mm)+BG-BG2:QAWord%IW43%IW6
    Distance measurement right (4 mA = 0 mm, 20 mA = 40 mm)+BG-BG3:QAWord%IW46%IW8
    Unused, configurable in- or output Q1 of left sensor+BG-BG2:Q1Bool%I0.2%I2.2
    TRUE = Object within range of left sensor+BG-BG2:Q2Bool%I0.3%I2.3
    Unused, configurable in- or output Q1 of right sensor+BG-BG3:Q1Bool%I0.4%I2.4
    TRUE = Object within range of right sensor+BG-BG3:Q2Bool%I0.5%I2.5
    Outputs
    TRUE = Switch on red light (bad part)+BG-P1-PF1Bool%Q0.0%Q2.0
    TRUE = Switch on yellow light (measurement in progress)+BG-P1-PF2Bool%Q0.1%Q2.1
    TRUE = Switch on green light (good part)+BG-P1-PF3Bool%Q0.2%Q2.2

    • QR marker
    • QR marker
    • Front cover label
    • Front cover label