General data

ParameterValue
Electrical connection24-pin IEEE 488 female (SysLink)
Ethernet RJ45
Pneumatic connectionTube with 4 mm outer diameter
Operating Voltage24 VDC
Printer operating voltage230 VAC
Operating pressure6 bar
I/O6 DI / 7 DO
Label printerThermo-direct printer
Programmable label design
Labelmedia on roll
Cutter cuts of media after printing
Dimenions (H x W x D)660 mm x 420 mm x 185 mm

PLC inputs & outputs for the application module

Digital inputs
DescriptionReference tag CP Lab addressCP Factory address
TRUE = X-axis in label pick-up position+PH-BG1%I0.0%I2.0
TRUE = X-axis in rear end position+PH-BG2%I0.1%I2.1
TRUE = Z-axis in upper end position+PH-BG3%I0.2%I2.2
TRUE = Z-axis in lower end position+PH-BG4%I0.3%I2.3
TRUE = Work piece present+PH-BG5%I0.4%I2.4
TRUE = Vacuum created+PH-BP6%I0.5%I2.5
Digital outputs
DescriptionReference tag CP Lab addressCP Factory address
Move X-axis (FALSE = to rear end position, TRUE = to label pick-up position)+PH-MB1%Q0.0%Q2.0
TRUE = Move Z-axis up+PH-MB3%Q0.2%Q2.2
TRUE = Move Z-axis down+PH-MB4%Q0.3%Q2.3
TRUE = Open Z-axis end position lock+PH-MB5%Q0.4%Q2.4
TRUE = Switch on vacuum+PH-MB6%Q0.5%Q2.5
TRUE = Switch on blower+PH-MB7%Q0.6%Q2.6
TRUE = Switch on label cutter+PH-TM8%Q0.7%Q2.7

All information on this page is subject to change without notice