- General
-
Order number D13013 Type code CP-AM-iDRILL-C21 Series CP Systems Categories Application module
- Description
-
The application module Drilling CPS drills 4 drilling holes into the lower part of the housing. The workpieces are recognized by the first light barrier when moving into the application module and the carrier will be stopped. When the carrier has been stopped, the workpiece will be checked.
The workpiece request checks if there is a front cover on the carrier. The workpiece request in the middle (2) checks if there is a back cover on the lower part. The left request checks if the front cover is in its correct position on the carrier.
When the front cover is in its correct position and there is no back cover on it, the first two drilling holes are drilled into the left side of the front cover. Then the X-axis moves to the right position and the two right drilling holes are drilled.
After that, the carrier leaves the application module iDrilling.
-
Attribute Value Electrical connection Power supply terminal
Ethernet RJ45Pneumatic connection Tube with 4 mm outer diameter Operating voltage 24 VDC Operating pressure 6 bar Controller Festo CECC-LK I/O 8 DI / 7 DO
Connected to internal controllerX-axis Linear, pneumatic
Stroke: 120 mm
Position detection: 2 end position sensorsZ-axis Linear, pneumatic
Stroke: 40 mm
Position detection: 2 end position sensorsDrilling unit Twin drill head
Drive: 24 VDC
Max. drilling diameter: 2 mm
Current limiter: 3 A
Drilling distance: 40 mmDimensions (H x W x D) 520 mm x 365 mm x 215 mm -
Integrated PLC
Description Reference Datatype Address Inputs TRUE = X-Axis in left end position +VN-BG1 Bool X2.0 TRUE = X-Axis in right end position +VN-BG2 Bool X2.1 FALSE = Front cover orientation correct +VN-BG3 Bool X2.2 TRUE = Front cover present +VN-BG4 Bool X2.3 TRUE = Z-Axis in upper end position +VN-BG5 Bool X2.4 TRUE = Z-Axis in lower end position +VN-BG6 Bool X2.5 TRUE = Back cover already present +VN-BG8 Bool X2.7 FALSE = Emergency stop switch pushed (n.c.) +K1-24VNA Bool X3.5 Outputs TRUE = Move X-axis left +VN-MB1 Bool X4.0 TRUE = Move X-axis right +VN-MB2 Bool X4.1 TRUE = Switch on drill 1 +VN-MB3 Bool X4.2 TRUE = Switch on drill 2 +VN-MB4 Bool X4.3 TRUE = Move z-axis up +VN-MB5 Bool X4.4 TRUE = Move z-axis down +VN-MB6 Bool X4.5 TRUE = Open z-axis end position lock +VN-MB7 Bool X4.6 -
-