- General
-
Order number D13024 Type code CP-AM-LABEL Series CP Systems Categories Application module
- Description
-
The module automatically applies a self-adhesive label that is freely printable to the work piece.
The print data are individually loaded into the printer in a job-controlled manner. The label is printed immediately before applying the label on the work piece.
The scope of the Labeling module includes the corresponding control software in the form of program blocks. Program blocks are also provided, which ensure the loading of the print data from MES4.
-
Attribute Value Electrical connection 24-pin IEEE 488 female (SysLink)
Ethernet RJ45Pneumatic connection Tube with 4 mm outer diameter Operating Voltage 24 VDC Printer operating voltage 230 VAC Operating pressure 6 bar I/O 6 DI / 7 DO Label printer Thermo-direct printer
Programmable label design
Labelmedia on roll
Cutter cuts of media after printingDimenions (H x W x D) 660 mm x 420 mm x 185 mm -
Application module interface (Syslink or analog terminal)
Description Reference Datatype Address
CP LabAddress
CP FactoryInputs TRUE = X-axis in label pick-up position +PH-BG1 Bool %I0.0 %I2.0 TRUE = X-axis in rear end position +PH-BG2 Bool %I0.1 %I2.1 TRUE = Z-axis in upper end position +PH-BG3 Bool %I0.2 %I2.2 TRUE = Z-axis in lower end position +PH-BG4 Bool %I0.3 %I2.3 TRUE = Work piece present +PH-BG5 Bool %I0.4 %I2.4 TRUE = Vacuum created +PH-BP6 Bool %I0.5 %I2.5 Outputs Move X-axis (FALSE = to rear end position, TRUE = to label pick-up position) +PH-MB1 Bool %Q0.0 %Q2.0 TRUE = Move Z-axis up +PH-MB3 Bool %Q0.2 %Q2.2 TRUE = Move Z-axis down +PH-MB4 Bool %Q0.3 %Q2.3 TRUE = Open Z-axis end position lock +PH-MB5 Bool %Q0.4 %Q2.4 TRUE = Switch on vacuum +PH-MB6 Bool %Q0.5 %Q2.5 TRUE = Switch on blower +PH-MB7 Bool %Q0.6 %Q2.6 TRUE = Switch on label cutter +PH-TM8 Bool %Q0.7 %Q2.7 -
-