General data

ParameterValue
Electrical connection24-pin IEEE 488 female (SysLink)
Analog terminal
Operating voltage24 VDC
I/O5 DI / 3 DO / 2 AI
Sensors2x optoelectronic distance sensor
Dimenions (H x W x D)396 mm x 255 mm x 777 mm

PLC inputs & outputs for the application module

Digital inputs
DescriptionReference tag CP Lab addressCP Factory address
TRUE = Work piece present+BG-BG1%I0.0%I2.0
Unused, configurable in- or output Q1 of left sensor+BG-BG2:Q1%I0.2%I2.2
TRUE = Object within range of left sensor+BG-BG2:Q2%I0.3%I2.3
Unused, configurable in- or output Q1 of right sensor+BG-BG3:Q1%I0.4%I2.4
TRUE = Object within range of right sensor+BG-BG3:Q2%I0.5%I2.5
Digital outputs
DescriptionReference tag CP Lab addressCP Factory address
TRUE = Switch on red light (bad part)+BG-P1-PF1%Q0.0%Q2.0
TRUE = Switch on yellow light (measurement in progress)+BG-P1-PF2%Q0.1%Q2.1
TRUE = Switch on green light (good part)+BG-P1-PF3%Q0.2%Q2.2
Analog inputs
DescriptionReference tag CP Lab addressCP Factory address
Distance measurement left (4 mA = 0 mm, 20 mA = 40 mm)+BG-BG2:QA%IW19%IW6
Distance measurement right (4 mA = 0 mm, 20 mA = 40 mm)+BG-BG3:QA%IW22%IW8

All information on this page is subject to change without notice