General data
Parameter | Value |
---|---|
Electrical connection | 24-pin IEEE 488 female (SysLink) Analog terminal 230/110 V power supply |
Logic operating voltage | 24 VDC |
Heating element operating voltage | 230 VAC |
Operating pressure | 6 bar |
I/O | 2 DO / 1 AI |
Temperaturmessung | PT100 temperatur probe Analog signal: 0 - 10 V |
Heating power | Switchable, 500 W or 1000 W |
Controlled system | Temperatur PTn PWM |
Dimensions (H x W x D) | 525 mm x 240 mm x 180 mm |
PLC inputs & outputs for the application module
Digital outputs
Description | Reference tag | CP Lab address | CP Factory address |
---|---|---|---|
TRUE = Switch on heater | +EB-KF1 | %Q0.0 | %Q2.0 |
Select heating power (FALSE = 500 W, TRUE = 1000 W) | +EB-KF2 | %Q0.1 | %Q2.1 |
Analog inputs
Description | Reference tag | CP Lab address | CP Factory address |
---|---|---|---|
Current temperature (0 V = 0 °C, 10 V = 200 °C) | +EB-BA1 | %IW19 | %IW6 |
All information on this page is subject to change without notice